AC Inlet
Models FSS21611S & FSS20811S
16 & 8 Channel Video Optical Systems include either one FRS21611S
Receiver & one FTS21611S Transmitter or one FRS20811S Receiver &
one FTS20811S Transmitter
Installation and
Operation Manual
Introduction
The NITEK FSS21611S (16 Channel) and FSS20811S (8 Channel) fiber transmitter and receiver sets, are a fiber-optic
Universal-Mode™ system which can operate on either single-mode or multi-mode fiber. Digital transmission provides
broadcast quality video performance and bi-directional data, up to distances of 20Km (single-mode) and 1.2Km (multi-
mode). The RS422/RS485 port allows for the use of camera controls, the system begins communicating after power-up.
NITEK ®
De Schans 19-21 2a
8231 KA Lelystad
Tel: +31(0)320-230005
WWW.NITEK.NL
USA
5410 Newport Drive, # 24
Rolling Meadows, IL 60008
Phone: (847) 259-8900
Fax: (847) 259-1300
WWW.NITEK.NET
EUROPE
09172013
680160113
Note: This installation should be made by a qualified
service person and conform with local codes.
Reduce risk of fire or electrical shock. Do not
expose this product to rain or moisture.
Safety
The FSS21611S & FSS20811S use a Class 1 laser system in accordance with IEC 60825-1.
It is always advisable to follow good practice when working with optical fiber systems. This includes:
• Do not stare with unprotected eyes at fiber ends or connector faces.
• Use only approved filtered or attenuating viewing devices.
• For other safety issues and advice on good practices associated with optical fiber systems see IEC 60825-1 or your
local safety officer
.
The FSS21611S and FSS20811S can be either rack mounted, or resting on a desktop.
NOTES:
1. Use all four mounting screws to properly secure the unit to the rack.
2. Mechanical loading - The mounting ears were designed for two ears to support one unit.
3. Cable space - Allow for proper bend radius of the fiber cable exiting the back of the unit. Do not exceed the recom-
mended minimum bend radius of fiber cable, as internal breakage can occur.
Device Mounting Options
Video BNC
Connectors
Data Port
for Camera
Control
Fiber Optic
Port (SC)
Vue de la page 0
1 2 3

Résumé du contenu

Page 1 - NITEK ®

AC Inlet Models FSS21611S & FSS20811S 16 & 8 Channel Video Optical Systems include either one FRS21611S Receiver & one FTS21611S Transmit

Page 2 - Installation Instructions

Installation Instructions Refer to the diagrams on the previous page and below for installation. Use best industry practices and follow all local bu

Page 3 - Troubleshooting

Troubleshooting Problem: No video present 1. Is the Power LED in the device illuminated? Answer — No  Check to insure power adapter is properly co