Nitek IPPWR16 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Nitek IPPWR16. Nitek IPPWR16 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Model IPPWR16
16 Port Gb PoE+ Surge Protector
Installation and
Operation Manual
Rev 052912
NITEK®
Europe Office:
De Schans 19-21 2a, 8231 KA Lelystad
The Netherlands
Tel: +31(0)320-230005
Fax: +31(0)320-282186
WWW.NITEK.NL
USA Office:
5410 Newport Drive, Rolling Meadows, IL 60008
Phone: (800) 529-8900
Fax: (847) 259-1300
WWW.NITEK.NET
68-016-0103
Specifications
Enclosure Type 19” rack, 2RU Height
Connection Method Standard RJ45
(16 In - 16 Out)
Clamping Voltage 58v (on all lines)
Network Type 10/100/1000
PoE+ or non-PoE
Temperature -40°C to +85°C
Installation
The IPPWR16 must be properly installed to insure maximum protection. The function of the IPPWR16 is to
allow a surge to be routed to ground and to clamp the protected equipment video inputs to a minimum voltage.
There are three key points to remember when installing the IPPWR16. First, provide a low impedance
connection between the IPPWR16 and your protected equipment. This is best done by keeping the PROTECTED
Ethernet cable connections as short as possible, ideally less than 3 feet.
Second, the system should use a single ground point. Connect the grounding stud of the IPPWR16 to a single
ground point. A single ground point is a proper building ground to which equipment grounds are connected. Ideally,
the protected equipment should be isolated from ground. If the IPPWR16 and the protected equipment are both
grounded you will provide a parallel path to ground and a portion of the surge current can flow through that path.
Additionally, AC power line protectors should be used to complete your surge protection strategy.
Finally, the UNPROTECTED cables and wires should not be crossed with the PROTECTED cables and wires.
Crossing cables could provide a path for surge currents to bypass the IPPWR16 protection circuits.
Description
The IPPWR16 is designed to provide 16 channels of
surge protection for network devices. It can be used
with both PoE+ and non-PoE devices. The
IPPWR16 is cost-effective and ideally suited for
protecting multi-input devices such as a network
hub, NVR, or groups of IP cameras or servers. The
IPPWR16 is rack mountable in a standard 19” rack.
It installs in minutes and provides a single easy
access point for grounding.
Network runs can be up
to 100 meters
IPPWR16
POE Switch
Up to 15.4 watts