Installation - continued
Step 5)
Connect the twisted pair to the terminals marked “WIRE
PAIR +” and “
-
”. Note the polarity of the connection. There is
also an “Earth Ground” terminal. If the “Earth Ground” is not
connected the unit will be grounded through the coax shield.
Set the transmitter DIP switches for the distance closest to
your application:
The settings listed are for normal conditions. Other set-
tings are possible. Switches 7 and 8 adjust sharpness and 5
and 6 adjust gain.
Switches (1 and 2) or (3 and 4) must be
operated together
.
Step 6)
The receiver unit should be powered using the wall pack
power supply provided with the unit. For multiple units a common
class 2 power supply may be used. There is no polarity for DC
Step 7)
You can now disconnect the test monitor and connect
the video out of the receiver unit as needed for your installa-
tion.
ffOerasnoitisoPdekramnU
oediV
niaGleveL
oediV
gnikaeP
ecnatsiD
noitisoPhctiwS
1234567 8
.tf005<
)m251(
.tf000,1
)m403(
NONO
.tf005,1
)m754(
NONONO
.tf000,2
)m016(
NONONONO
.tf005,2
)m267(
NONONONONONO
.tf000,3
)m519(
NONONONONONONO