Troubleshooting
After completing installation, if the units are not operating properly, check each step at each unit in order.
1) If the Power LED is off verify the unit’s power connections and verify that the power source is on an active
circuit.
2) If the link status LED does not stop blinking, verify that the UTP cable has been properly installed and make sure
the receiver’s link Type LED is “OFF” and that the transmitter’s link Type LED is “ON”.
3) If the Activity LED is “OFF” verify you have power to the camera and good connections to the RJ45 connectors.
4) If the activity LED is “ON” and the link status LED is “ON” and there is no picture, verify camera IP address and
monitoring IP address are proper and refresh the monitor. Directly attach the camera through a short patch cable
directly to NVR/IP network. Verify that camera and monitor programs are properly functioning.
Install Network to VR448UTP and IP Cameras
1) Connect an earth ground to each unit before making any additional connections.
2) Connect a network cable from the receiver to the security room or IP network equipment.
3) Connect a UTP cable between the transmitter and the receiver. The transmitter uses an RJ45 jack where the center
two pins (4,5) are the output signal. The receiver uses an RJ6 jack where the center two pins (3,4) are the output
signal.
4) Connect a network cable from the transmitter’s four Ethernet jacks to the IP cameras or other network devices.
5) Connect the Class 2 power transformer to the push in power connector of the VR448UTP receiver. The unit
requires 24VAC or VDC @ 1 Amp. There is no polarity to these terminals.
6) Connect the 48VDC 1A power supply to the power connector of the VR448UTP transmitter.
.
Normal Operation
When power is applied to both units the Network LED’s will come on and the link status LED will blink for about 30
seconds as the link is being optimized. When the link is stable the link status LED will remain “ON”. The Ethernet data
LED will blink with network activity.
VR448UTP Network Extender Installation Drawing
!
The separate protective earthing terminal provided on this product shall be permanently connected to earth.
NVR
Power
Transformer
VR448UTP
Receiver
VR448UTP
Transmitter
w/PoE
1 mile (1,600 m)
24AWG or Better
UTP Twisted Pair
IP Cameras
Network Cable
Network Cable
Power
Transformer
Ground
Wire
Ground
Wire
VR448UTP
Receiver
Vue de la page 1
1 2

Commentaires sur ces manuels

Pas de commentaire